The pilot light on a Rheem furnace is a small but critical component that ignites the main burner. This article explains common pilot light problems, step-by-step troubleshooting, safety precautions, and maintenance tips to keep a Rheem furnace operating reliably. The guidance applies to most Rheem and Ruud gas furnaces with a standing pilot system.
| Issue | Common Causes | Quick Fix |
|---|---|---|
| Pilot Won’t Stay Lit | Faulty thermocouple, dirty pilot, draft | Clean pilot, replace thermocouple |
| Pilot Won’t Light | Gas supply off, clogged orifice, defective igniter | Check gas valve, clean orifice, test igniter |
| Yellow Or Sooty Flame | Incomplete combustion, insufficient air | Adjust airflow, clean burner |
Content Navigation
- Pilot Light Basics For Rheem Furnaces
- Key Components Of The Pilot Assembly
- Common Symptoms And What They Mean
- Safety First: Precautions Before Any Work
- Step-By-Step Troubleshooting
- When To Call A Professional
- Maintenance Practices To Prevent Pilot Problems
- Parts, Tools, And Typical Costs
- Model-Specific Notes For Rheem And Ruud
- Common Myths And Clarifications
- DIY Replacement Steps For Thermocouple (Overview)
- Troubleshooting Checklist
- Carbon Monoxide Awareness And Testing
- Resources And Manuals
- Key Takeaways
Pilot Light Basics For Rheem Furnaces
The pilot light is a continuously burning flame that ignites the main burners when the thermostat calls for heat. Many modern Rheem furnaces use electronic ignition or hot surface igniters, but older models and some current lines still include a standing pilot assembly. Understanding the pilot system components helps diagnose issues quickly.
Key Components Of The Pilot Assembly
Pilot Orifice: A small nozzle that meters gas to the pilot flame. Thermocouple: A safety sensor that detects the pilot flame and keeps the gas valve open. Pilot Tube: Carries gas from the orifice to the flame. Pilot Adjustment Screw: Controls flame size on some models.
Common Symptoms And What They Mean
Recognizing symptoms helps narrow causes. A pilot that lights but won’t stay lit often indicates a thermocouple issue or a weak flame. A pilot that won’t light at all may point to a gas supply problem, blocked orifice, or a failed igniter. A yellow, lazy, or sooty flame suggests combustion problems or partial obstruction.
Safety First: Precautions Before Any Work
Gas and flame work can be dangerous. Turn off the gas supply at the furnace valve before inspecting or cleaning the pilot assembly. If a strong gas odor is present, evacuate the area and call the gas utility or emergency services. Use a compact flame-resistant flashlight and never use matches indoors while working on a furnace.
Step-By-Step Troubleshooting
1. Verify Gas Supply And Thermostat
Confirm the furnace gas valve is on and other gas appliances operate. Check the thermostat set point and batteries. If the furnace has an on/off switch on the unit, ensure it is in the on position. These basic checks eliminate simple causes before deeper inspection.
Call 888-896-7031 for Free Local HVAC Quotes – Compare and Save Today!
2. Inspect Pilot Flame Shape And Color
A healthy pilot flame should be blue and steady, wrapping the thermocouple tip. A weak, off-center, or yellow flame suggests a clogged orifice, draft, or combustion air shortage. Note the flame behavior while the furnace is attempting to light to inform the next steps.
3. Clean The Pilot Orifice And Tube
Turn off gas and allow components to cool. Use compressed air, a soft brush, or a thin wire to dislodge debris from the orifice and pilot tube. Reassemble and relight following manufacturer instructions. Cleaning often restores a weak pilot flame.
4. Test And Replace The Thermocouple
The thermocouple converts heat to a small electrical current that keeps the gas valve open. If the pilot lights but the furnace shuts off quickly, the thermocouple may not generate sufficient millivolts. Measure output with a multimeter while the pilot is lit; values below the furnace spec (commonly 25–30 mV) indicate replacement is needed.
5. Check The Pilot Adjustment And Airflow
Some Rheem units have an adjustment screw at the pilot assembly. Carefully adjust to increase flame size if it’s too small, following the service manual. Also inspect for drafts from holes or gaps near the furnace that can blow the pilot out; sealing drafts or repositioning nearby items can stabilize the flame.
6. Inspect The Gas Valve And Control Components
If the pilot won’t light despite a strong flame and good thermocouple, the gas valve or control module could be faulty. Valves can fail internally or have blocked internal passages. Testing and replacement of gas valves should be performed by a licensed technician due to regulatory and safety requirements.
7. Evaluate For Venting Or Combustion Problems
Inadequate combustion air, blocked flue, or damaged venting can affect pilot flame quality and overall furnace operation. Inspect vents, draft hoods, and chimney connectors for obstruction or corrosion. Correct venting issues promptly to avoid carbon monoxide risks.
Call 888-896-7031 for Free Local HVAC Quotes – Compare and Save Today!
When To Call A Professional
Call a licensed HVAC technician if troubleshooting points to a faulty gas valve, persistent combustion irregularities, or if the pilot issue recurs after repairs. Professionals have proper tools for leak testing, millivolt measurement, and gas valve replacement and can ensure work complies with local codes.
Maintenance Practices To Prevent Pilot Problems
Regular preventive maintenance reduces pilot-related failures. Recommended tasks include annual inspections, cleaning the pilot orifice and burner, checking thermocouple output, and verifying proper venting. Replace worn components before they fail to avoid mid-winter breakdowns.
Parts, Tools, And Typical Costs
Common parts include thermocouples, pilot orifice kits, and gas valves. Basic tools for pilot troubleshooting: adjustable wrench, soft brush, compressed air, multimeter, and needle pick. Typical cost ranges: thermocouple $15–$60, pilot orifice kit $10–$30, gas valve $150–$600 plus labor. Prices vary by model and region.
Model-Specific Notes For Rheem And Ruud
Rheem and Ruud share many design elements and parts compatibility. Some Rheem furnaces use electronic ignition systems that eliminate a standing pilot; in those models, pilot troubleshooting is not applicable. Always consult the furnace’s model number and service manual before beginning any work.
Common Myths And Clarifications
Myth: A bigger pilot flame is always better. Clarification: An oversized flame can overheat the thermocouple and waste gas; follow manufacturer specifications. Myth: Thermocouple testing isn’t necessary if the flame looks strong. Clarification: Visual checks can be misleading; millivolt testing verifies thermocouple function.
DIY Replacement Steps For Thermocouple (Overview)
Turn off gas and power, remove access panels, locate the thermocouple where it meets the pilot assembly, loosen the nut that attaches it to the gas valve, unclip the bracket and slide out the old thermocouple, install the new one ensuring the tip sits fully in the pilot flame, tighten connections, restore gas, and test operation. If unsure, hire a technician.
Troubleshooting Checklist
- Verify Gas On: Ensure the furnace gas valve and house gas shutoff are open.
- Check Thermostat: Confirm correct mode and set point.
- Observe Flame: Look for blue color and stability around the thermocouple.
- Clean Orifice: Remove debris and test flame again.
- Measure Thermocouple: Use a multimeter to check millivolts while lit.
- Inspect Venting: Look for obstructions or corrosion.
- Call Pro: If gas valve suspected or complex repairs needed.
Carbon Monoxide Awareness And Testing
Pilot and combustion problems can increase carbon monoxide risk. Install a certified carbon monoxide detector near sleeping areas and follow testing and replacement schedules. If the furnace produces soot, yellow flames, or occupants experience headaches or dizziness, stop using the furnace and seek immediate professional help.
Resources And Manuals
Model-specific Rheem owner’s manuals provide pilot assembly diagrams, part numbers, and safety procedures. Rheem’s official support site and authorized service centers offer diagnostics and OEM parts. Local utility companies often provide safety information and can assist with gas leak concerns.
Key Takeaways
Regular cleaning, proper thermocouple function, and correct venting are the most common determinants of a reliable Rheem furnace pilot light. Simple maintenance resolves many issues, but any gas valve replacements or persistent combustion problems require a licensed technician to ensure safety and code compliance.
Tips for Getting the Best HVAC Prices
- Prioritize Quality Over Cost
The most critical factor in any HVAC project is the quality of the installation. Don’t compromise on contractor expertise just to save money. - Check for Rebates
Always research current rebates and incentives — they can significantly reduce your overall cost. - Compare Multiple Quotes
Request at least three estimates before making your choice. You can click here to get three free quotes from local professionals. These quotes include available rebates and tax credits and automatically exclude unqualified contractors. - Negotiate Smartly
Once you've chosen a contractor, use the proven strategies from our guide — How Homeowners Can Negotiate with HVAC Dealers — to get the best possible final price.
| Action | When To Do It |
|---|---|
| Clean Pilot Orifice | Annually Or If Flame Weak |
| Test Thermocouple | If Pilot Won’t Stay Lit |
| Inspect Venting | Annually Or After Soot/Yellow Flame |
| Call Technician | Gas Valve Suspected Or Persistent Issues |