When A Brand New Heat Pump Is Not Cooling, It Can Be Frustating And Costly. This Article Explains Common Causes, Step-By-Step Troubleshooting, And Practical Fixes For Homeowners And Technicians. It Focuses On Diagnostics That Apply To Modern Heat Pump Systems, Warranty Considerations, And When To Call Professional Service.
| Symptom | Possible Causes | Quick Actions |
|---|---|---|
| Warm Or Lukewarm Air | Incorrect Refrigerant Charge, Reversing Valve Issue, Thermostat Mode | Check Thermostat Settings, Inspect Outdoor Unit, Call Installer |
| Insufficient Airflow | Clogged Filter, Closed Vents, Blower Problem | Replace Filter, Open Vents, Verify Blower Operation |
| Ice On Indoor Or Outdoor Coil | Low Refrigerant, Defrost Cycle Failure | Turn Off Unit To Thaw, Document And Report |
| Short Cycling Or Frequent Trips | Electrical Issues, Incorrect System Sizing | Check Breakers, Review Installer Commissioning |
Content Navigation
- How Heat Pumps Cool: Basic Principles
- Common Reasons A Brand New Heat Pump Is Not Cooling
- Initial Troubleshooting Steps Homeowners Can Do
- Diagnostic Checks A Technician Will Perform
- Common Repair And Correction Actions
- Warranty, Installer Responsibilities, And Documentation
- When To Call The Installer Versus A Third-Party Technician
- Preventive Measures To Avoid Cooling Problems
- Frequently Asked Questions
- Key Takeaways For Homeowners
How Heat Pumps Cool: Basic Principles
A Heat Pump Transfers Heat By Circulating Refrigerant Between Indoor And Outdoor Coils. In Cooling Mode, The Indoor Coil Acts As An Evaporator Absorbing Indoor Heat, While The Outdoor Coil Releases Heat To Outside Air. A Reversing Valve Changes Mode Between Heating And Cooling.
Modern Units Include Components Like The Compressor, Expansion Device, Reversing Valve, Reverses, Fans, And Controls. Proper Refrigerant Charge, Airflow, And Control Signals Are Essential For Cooling Performance.
Common Reasons A Brand New Heat Pump Is Not Cooling
Wrong Thermostat Settings Or Mode
Often A New System Fails To Cool Because The Thermostat Is Set To Heat Or Auto With A High Differential. Verify The Thermostat Is In Cooling Mode And Set At Least 5°F Below Room Temperature For Testing.
Commissioning And Startup Issues
New Installations Require Commissioning: Proper Refrigerant Charge, Electrical Connections, And Control Configuration. An Uncommissioned Unit May Run But Not Cool Effectively. Review The Installer Checklist And Request A Commissioning Report.
Incorrect Refrigerant Charge
Even New Units Can Be Undercharged Or Overcharged If Line Sets Are Incorrectly Charged After Installation. Incorrect Charge Reduces Capacity And Can Cause Coil Icing Or High Head Pressures.
Call 888-896-7031 for Free Local HVAC Quotes – Compare and Save Today!
Reversing Valve Stuck Or Miswired
The Reversing Valve Switches The System Between Heating And Cooling. A Faulty Valve Or Incorrect Control Wiring Can Keep The System In Heating Mode Or A Transitional State, Producing Warm Air.
Improper Airflow
Restricted Airflow From Dirty Filters, Closed Registers, Duct Leaks, Or Blower Motor Problems Limits Heat Transfer, Causing The Heat Pump To Run But Deliver Little Cooling.
Defrost Cycle Misbehavior
If The Outdoor Unit Is Icing Or The Defrost Control Is Faulty, The System May Enter Frequent Defrost Or Fail To Defrost Properly, Reducing Cooling Capacity.
Electrical Or Control Failures
Loose Wiring, Tripped Breakers, Failed Relays, Or A Bad Contactor Can Interrupt Compressor Or Fan Operation, Resulting In No Or Poor Cooling.
Incorrect System Sizing Or Duct Design
An Oversized Or Undersized Heat Pump Or Poorly Designed Ductwork Can Cause Short Cycling, Humidity Problems, And Perceived Lack Of Cooling Even When The Unit Is Operating.
Factory Defect Or Damaged Component
Although Rare, Manufacturing Defects, A Damaged Compressor, Or A Faulty Reversing Valve Can Be Present In New Units. Document Symptoms Immediately For Warranty Claims.
Call 888-896-7031 for Free Local HVAC Quotes – Compare and Save Today!
Initial Troubleshooting Steps Homeowners Can Do
Verify Thermostat And Settings
Confirm The Thermostat Is In Cooling Mode, Fan Set To Auto, And The Setpoint Is Several Degrees Below Room Temperature. Ensure Any Programmable Schedule Is Not Forcing Heat.
Inspect Indoor And Outdoor Units
Look For Ice On Coils, Debris Around The Outdoor Unit, Or Visible Damage. Ensure Outdoor Unit Has At Least 2 Feet Clearance And The Condenser Fan Is Spinning When Running.
Check Air Filters And Vents
Replace Or Clean Filters If Dirty And Open All Supply Registers. Restricted Intake Or Closed Supply Vents Can Severely Reduce Cooling Output.
Listen And Observe Cycling
When The System Starts, Note Whether The Compressor Engages, The Outdoor Fan Runs, And If The Indoor Blower Moves Air. Document Any Clicking, Humming, Or Short Run Periods.
Check Breakers And Disconnects
Confirm The Heat Pump Breaker And Outdoor Disconnect Are On. Reset Any Tripped Breakers And Note If They Re-Trip, Which Indicates An Electrical Or Compressor Problem.
Diagnostic Checks A Technician Will Perform
Measure Refrigerant Pressures
A Technician Uses Gauges To Check Suction And Discharge Pressures And Compares Them To Manufacturer Targets For The Install Conditions. Pressure Readings Reveal Undercharge, Overcharge, Or Flow Restrictions.
Evaluate Superheat And Subcooling
Superheat And Subcooling Calculations Verify Proper Refrigerant Charge And Expansion Device Performance. Deviations Indicate Charging Or Component Issues.
Test Reversing Valve And Electrical Controls
Technicians Energize And Observe The Reversing Valve Position And Use Meters To Check Control Signals, Contactors, And Transformer Voltages To Ensure Correct Mode Switching.
Check Defrost Control And Sensors
Defrost Control Boards, Outdoor Sensors, And Cycle Timers Are Tested For Proper Operation. A Failed Defrost Control Can Make The Outdoor Coil Remain Iced, Reducing Cooling.
Inspect Ductwork And Airflow Parameters
A Contractor Measures Static Pressure, Supply And Return Temperatures, And Airflow CFM To Diagnose Duct Restrictions, Leaks, Or Blower Issues That Reduce Cooling Capacity.
Common Repair And Correction Actions
Correct Refrigerant Charge
If Measurements Indicate An Incorrect Charge, A Qualified Technician Will Recover, Evacuate, And Recharge The System To Manufacturer Specifications. Never Add Or Remove Refrigerant Without Proper Tools.
Repair Or Replace Reversing Valve
A Stuck Or Faulty Reversing Valve Requires Service Or Replacement. Technicians Inspect Valve Actuation, Wiring, And Pressure Conditions Before Replacing The Valve Or Coil Assembly.
Restore Proper Airflow
Solutions Include Replacing Filters, Clearing Obstructed Returns, Adjusting Dampers, Sealing Leaky Ducts, Or Replacing A Failing Blower Motor. Improving Airflow Often Improves Capacity And Comfort.
Fix Electrical And Control Issues
Repairing Loose Connections, Replacing Contactors, Relays, Or Control Boards, And Ensuring Correct Thermostat Wiring Resolves Many Startup Problems. Technicians Also Verify Proper Breaker Sizing And Voltage.
Address Defrost And Sensor Failures
Replacing Faulty Defrost Controls Or Sensors And Confirming Proper Drainage Prevents Coil Ice Build-Up And Restores Normal Cooling Operation.
Warranty, Installer Responsibilities, And Documentation
New Heat Pumps Are Typically Covered By Manufacturer Warranties For Major Components. The Installer Should Provide A Startup Checklist And Commissioning Report Showing Proper Charge And Operation.
Homeowners Should Document Dates, Symptoms, Photos, And Conversations When Reporting Issues. Early Reporting Helps Preserve Warranty Coverage And Ensures The Installer Corrects Installation Errors Promptly.
When To Call The Installer Versus A Third-Party Technician
The Installer Should Be Contacted First If The Unit Was Recently Installed, As Installation Errors Are Their Responsibility Under Most Warranties. If The Installer Is Unresponsive, A Licensed HVAC Contractor Can Diagnose And Provide A Written Report To Pursue Warranty Claims.
Homeowners Should Avoid DIY Refrigerant Work Because It Can Void Warranties And Violate Regulations. Electrical Work Should Be Handled By Qualified Professionals.
Preventive Measures To Avoid Cooling Problems
- Schedule A Professional Commissioning After Installation To Verify Charge And Controls.
- Change Or Clean Filters Every 1–3 Months Depending On Use And Indoor Conditions.
- Maintain Clearances Around Outdoor Units And Trim Vegetation To Ensure Adequate Airflow.
- Keep Ductwork Sealed And Insulated, Especially In Unconditioned Spaces.
- Program Thermostat For Reasonable Setbacks But Avoid Rapid Big Setpoint Changes.
Frequently Asked Questions
Can A New Heat Pump Be Low On Refrigerant?
Yes. Although New Systems Are Charged At The Factory, Refrigerant Can Be Lost During Line Set Installation Or If A Leak Occurred During Shipping Or Handling. Proper Commissioning Detects This.
Is Warm Air Always A Compressor Problem?
Not Always. Warm Air Can Result From Thermostat Mode, Reversing Valve Issues, Poor Airflow, Or Incorrect Refrigerant Charge. A Complete Diagnostic Is Required.
How Long Should A New Heat Pump Run Before Cooling Is Noticeable?
A Heat Pump Should Produce Cooler Supply Air Within A Few Minutes Of Compressor Start. Full Room Cooling Depends On Load, But Significant Cooling Should Be Evident Within 15–30 Minutes.
Key Takeaways For Homeowners
When A Brand New Heat Pump Is Not Cooling, Initial Checks Include Thermostat Mode, Filters, Vents, And Breakers. If Problems Persist, Contact The Installer For Commissioning And Warranty Service. Professional Diagnostics For Refrigerant, Reversing Valve, And Airflow Are Often Required To Restore Proper Cooling.
Document Symptoms, Avoid DIY Refrigerant Work, And Insist On A Commissioning Report To Ensure The System Performs As Specified.
Tips for Getting the Best HVAC Prices
- Prioritize Quality Over Cost
The most critical factor in any HVAC project is the quality of the installation. Don’t compromise on contractor expertise just to save money. - Check for Rebates
Always research current rebates and incentives — they can significantly reduce your overall cost. - Compare Multiple Quotes
Request at least three estimates before making your choice. You can click here to get three free quotes from local professionals. These quotes include available rebates and tax credits and automatically exclude unqualified contractors. - Negotiate Smartly
Once you've chosen a contractor, use the proven strategies from our guide — How Homeowners Can Negotiate with HVAC Dealers — to get the best possible final price.