The Coleman furnace pilot light keeps older gas furnaces running reliably, but when it goes out or burns weakly, homeowners need clear steps to diagnose, relight, and prevent future problems. This article explains how a Coleman furnace pilot light works, common causes for failure, safe relighting procedures, troubleshooting tips, and when to call a licensed HVAC technician. Key takeaway: many pilot light issues are simple to fix, but persistent problems or gas odors require professional service.
| Symptom | Likely Cause | Quick Fix |
|---|---|---|
| Pilot Won’t Stay Lit | Faulty thermocouple or draft | Replace thermocouple, shield from drafts |
| Pilot Flickers Or Burns Yellow | Dirty pilot or low gas pressure | Clean pilot assembly, check gas supply |
| Gas Smell | Leak in line or valve | Evacuate, call gas company/technician |
Content Navigation
- How A Coleman Furnace Pilot Light Works
- Common Reasons A Coleman Furnace Pilot Light Goes Out
- Troubleshooting Steps Before Relighting
- How To Relight A Coleman Furnace Pilot Light Safely
- Cleaning And Minor Repairs For Pilot Issues
- When To Call A Professional HVAC Technician
- Maintenance Practices To Prevent Pilot Light Problems
- Replacement Parts, Costs, And Where To Buy
- Safety Risks And Carbon Monoxide Considerations
- Model-Specific Tips For Coleman Furnaces
- Frequently Asked Questions About Coleman Furnace Pilot Light
- Practical Checklist For Homeowners
- Resources And Next Steps
How A Coleman Furnace Pilot Light Works
The pilot light is a small, continuous flame that ignites the main burners when the thermostat calls for heat. On many Coleman furnaces, a thermocouple or flame sensor detects the pilot and permits the gas valve to open. If the pilot light is out or the sensor doesn’t register flame, a safety mechanism prevents gas flow to the burners.
Key Components: pilot orifice, thermocouple (or flame sensor), gas valve, pilot tubing, and the pilot shield or assembly. Proper operation depends on correct flame shape, stable gas pressure, and an unobstructed pilot orifice.
Common Reasons A Coleman Furnace Pilot Light Goes Out
Several mechanical and environmental issues can extinguish a pilot light. Identifying the most probable cause helps direct the right solution quickly.
- Faulty Thermocouple Or Flame Sensor: Worn sensors fail to detect flame and shut off gas as a safety measure.
- Pilot Orifice Clog: Dirt, dust, or spider webs reduce fuel flow and weaken the flame.
- Drafts Or Airflow: Nearby vents, fans, or house drafts can blow out the pilot flame.
- Gas Supply Or Pressure Issues: Low house gas pressure or a closed shutoff valve reduces flame strength.
- Valve Problems: A malfunctioning gas control valve may not supply pilot gas consistently.
- Age And Corrosion: Corroded tubing or fittings can restrict flow or fail mechanically.
Troubleshooting Steps Before Relighting
Before attempting to relight a Coleman furnace pilot light, follow a sequence of checks to ensure safety and increase the chance of a lasting fix.
- Turn off the furnace at the thermostat and the power switch to prevent unintended startup.
- Smell for gas: Any gas odor requires immediate action. Do not light the pilot if a gas smell is present; evacuate and call the gas company or 911.
- Confirm the gas shutoff valve to the furnace is open.
- Inspect for drafts, open windows, or exhaust fans near the furnace that could blow out the pilot.
- Look for soot or a yellow pilot flame, which indicates combustion issues or low gas pressure.
How To Relight A Coleman Furnace Pilot Light Safely
Relighting the pilot on a Coleman furnace is straightforward, but safety precautions matter. Follow the furnace manufacturer’s label instructions when present.
Call 888-896-7031 for Free Local HVAC Quotes – Compare and Save Today!
- Turn Off Gas And Power: Set the gas control knob to OFF and wait 5–10 minutes for any accumulated gas to clear.
- Set To Pilot: Turn the gas control knob to the PILOT position and press down to start gas flow to the pilot.
- Ignite The Pilot: While holding the knob, use the furnace’s built-in piezo igniter or a long-reach lighter to light the pilot. Continue holding the knob for 30–60 seconds so the thermocouple heats and recognizes the flame.
- Release Slowly: Let the knob return to the on position if the pilot stays lit. Switch the furnace back to AUTO or ON and restore power.
- Observe Flame: The pilot flame should be blue and fully envelop the thermocouple tip. Weak or yellow flames indicate a problem that needs further attention.
Important Safety Tip: If the pilot will not stay lit after several attempts, stop and contact a licensed technician. Repeated attempts can allow gas buildup or indicate a dangerous component failure.
Cleaning And Minor Repairs For Pilot Issues
Some pilot light problems are resolved by cleaning or small part replacements. These tasks are feasible for homeowners comfortable with basic tools and safety procedures.
- Clean The Pilot Orifice: Turn off gas, remove access panels, and use compressed air or an appropriate-size wire/needle to gently clear the orifice. Do not enlarge the hole.
- Clean Thermocouple Connection: Remove and gently clean with fine sandpaper or steel wool, then reconnect securely to the gas valve.
- Check Thermocouple Position: Ensure the thermocouple tip sits in the pilot flame; adjust the bracket if it’s misaligned.
- Replace Worn Thermocouple: Thermocouples are inexpensive and commonly fail after years of use. Replace with an exact match for safety and reliable operation.
When To Call A Professional HVAC Technician
Homeowners should enlist a licensed HVAC or gas technician for any issue outside routine cleaning, or when safety concerns exist.
- Persistent Pilot Outages: Repeated failure after cleaning and thermocouple replacement indicates valve or regulator trouble.
- Gas Odor Or Suspected Leak: Evacuate and call the gas company and a technician immediately.
- Yellow Or Sooting Flames: Suggest incomplete combustion or blocked venting—possible carbon monoxide risk.
- Age-Related Failures: Older Coleman furnaces may have multiple worn components needing comprehensive inspection and potential replacement.
Maintenance Practices To Prevent Pilot Light Problems
Regular maintenance increases reliability and longevity of a Coleman furnace pilot light while improving safety and efficiency.
- Annual Professional Tune-Up: A certified HVAC technician should inspect burners, pilot assembly, gas pressure, and safety devices.
- Keep Area Clean: Prevent dust, debris, and insects from entering the pilot orifice and burner compartment.
- Check Venting: Maintain clear flue and vent pipes to ensure proper draft and exhaust of combustion gases.
- Inspect For Drafts: Seal nearby gaps or relocate fans that create drafts around the furnace.
- Replace Aging Components: Replace thermocouples, pilot tubing, and controls proactively when worn or during major service visits.
Replacement Parts, Costs, And Where To Buy
Knowing common parts and ballpark costs helps homeowners plan repairs. Prices vary by model and region.
| Part | Typical Cost Range | Notes |
|---|---|---|
| Thermocouple | $10–$50 | Common DIY replacement; match length and thread. |
| Pilot Orifice | $5–$25 | Often sold with pilot assembly; requires correct size. |
| Gas Control Valve | $150–$600 | Higher cost; professional replacement recommended. |
| Pilot Assembly | $30–$150 | Includes tubing and bracket; useful when multiple components show wear. |
Safety Risks And Carbon Monoxide Considerations
A malfunctioning pilot or burner can cause incomplete combustion, producing carbon monoxide (CO). CO is colorless and odorless and poses a serious health hazard. Homes with gas furnaces should have working CO detectors near sleeping areas and on each level.
Call 888-896-7031 for Free Local HVAC Quotes – Compare and Save Today!
Safety Actions: Replace batteries in CO detectors annually, schedule professional combustion analysis if yellow flames or soot appear, and ensure venting paths are unobstructed to prevent CO buildup.
Model-Specific Tips For Coleman Furnaces
Coleman furnaces vary by age and model, but pilot systems generally share common components. Consult the furnace data plate or owner manual for model-specific pilot location and lighting instructions. OEM replacement parts ensure compatibility and safe operation.
- Older Coleman Units: More likely to have standing pilot systems, which need periodic thermocouple replacement.
- Newer Units: May use electronic ignition systems that eliminate a constant pilot light and reduce pilot-related service calls.
- OEM Versus Aftermarket Parts: OEM parts match specifications; high-quality aftermarket parts can be acceptable if they match dimensions and ratings.
Frequently Asked Questions About Coleman Furnace Pilot Light
Why Does The Pilot Light Burn Yellow?
A yellow or sooty pilot flame indicates incomplete combustion often caused by dirt in the orifice, incorrect gas pressure, or improper air-to-fuel ratio. Cleaning and professional combustion testing are recommended.
How Long Should The Pilot Flame Stay Lit After Relighting?
If the thermocouple and valve are functioning, the pilot should remain lit indefinitely. If it goes out within seconds after the knob is released, the thermocouple is likely failing and should be replaced.
Is It Safe To Relight The Pilot Myself?
Yes, if there is no gas smell and the homeowner follows the manufacturer instructions and safety steps. If there is any doubt or repeated failure, contact a professional.
Can A Dirty Pilot Cause High Heating Bills?
Yes. A weak pilot can cause incomplete combustion and inefficient burner operation, leading to higher energy use and uneven heating.
Practical Checklist For Homeowners
- Inspect pilot flame color and stability monthly during heating season.
- Clean the furnace area and remove debris that can enter the pilot assembly.
- Test CO detectors monthly and replace batteries annually.
- Keep a spare thermocouple and small tools if comfortable performing simple replacements.
- Schedule a professional tune-up before the heating season.
Resources And Next Steps
For model-specific guidance, refer to the Coleman furnace manual or the data plate on the furnace. For gas leaks, evacuation and immediate contact with the gas company and a licensed HVAC technician are essential. Regular maintenance and prompt attention to pilot light problems will keep a Coleman furnace safe, efficient, and reliable throughout the heating season.
Tips for Getting the Best HVAC Prices
- Prioritize Quality Over Cost
The most critical factor in any HVAC project is the quality of the installation. Don’t compromise on contractor expertise just to save money. - Check for Rebates
Always research current rebates and incentives — they can significantly reduce your overall cost. - Compare Multiple Quotes
Request at least three estimates before making your choice. You can click here to get three free quotes from local professionals. These quotes include available rebates and tax credits and automatically exclude unqualified contractors. - Negotiate Smartly
Once you've chosen a contractor, use the proven strategies from our guide — How Homeowners Can Negotiate with HVAC Dealers — to get the best possible final price.