A Goodman heat pump not cooling can be disruptive and costly if left unresolved. This guide helps identify common causes, step-by-step troubleshooting, maintenance tips, and when to call a technician, giving homeowners practical, safe actions to restore cooling performance.
| Symptom | Likely Cause | Quick Action |
|---|---|---|
| Unit Won’t Turn On | Power Issue, Tripped Breaker | Check Breaker, Reset Disconnect |
| Runs But No Cool Air | Refrigerant Leak, Reversing Valve | Inspect Coils, Call Technician |
| Short Cycling | Thermostat Or Compressor Issue | Check Thermostat Settings |
| Frozen Coils | Low Refrigerant, Poor Airflow | Turn Off Unit, Thaw, Check Filters |
Content Navigation
- How A Goodman Heat Pump Cooling System Works
- Common Reasons A Goodman Heat Pump Is Not Cooling
- Step-By-Step Troubleshooting For Homeowners
- DIY Fixes Homeowners Can Safely Attempt
- When To Call A Professional Technician
- What To Expect From A Pro Diagnosis
- Estimated Repair Costs And Timeframes
- Preventive Maintenance To Avoid Cooling Failures
- Troubleshooting Table: Symptoms, Causes, Actions
- Goodman Heat Pump Warranties And Parts
- When Replacement Is The Best Option
- Energy Efficiency And Savings Tips
- Frequently Asked Questions
- Choosing A Qualified HVAC Technician
- Key Takeaways
How A Goodman Heat Pump Cooling System Works
A Goodman heat pump transfers heat by circulating refrigerant between an indoor evaporator coil and an outdoor condenser coil while the reversing valve determines heating or cooling mode. In cooling mode, the system extracts indoor heat and rejects it outdoors. Proper operation depends on electrical components, refrigerant charge, airflow, and controls.
Common Reasons A Goodman Heat Pump Is Not Cooling
Insufficient Refrigerant Charge
Low refrigerant is a common cause of poor cooling. Leaks reduce the system’s ability to absorb heat and can cause the evaporator coil to freeze, lowering efficiency and airflow.
Electrical Or Power Failures
Tripped breakers, blown fuses, or a tripped disconnect at the outdoor unit will prevent the compressor or fan from running, producing no cooling despite thermostat calls for cooling.
Dirty Or Blocked Air Filters And Coils
Restricted airflow from clogged filters, dirty evaporator coils, or blocked outdoor coils reduces heat transfer. Poor airflow forces the system to work harder and may lead to coil icing and compressor strain.
Faulty Reversing Valve Or Defrost Cycle Issues
If the reversing valve sticks or the defrost control malfunctions, the unit may be stuck in heating or enter excessive defrost cycles, disrupting normal cooling operation.
Call 888-896-7031 for Free Local HVAC Quotes – Compare and Save Today!
Faulty Compressor Or Capacitor
A failed compressor or damaged start/run capacitor can stop the system from compressing refrigerant or starting, causing the heat pump not to cool even when fans run.
Thermostat Malfunctions Or Settings
Incorrect thermostat settings, wiring faults, or a failed thermostat sensor can prevent the heat pump from receiving the proper cooling call or engaging the outdoor unit.
Step-By-Step Troubleshooting For Homeowners
Safety First
Before inspecting, turn off power at the outdoor disconnect and circuit breaker. Only proceed with visual checks and non-invasive tasks unless qualified to work on electrical or refrigerant systems.
Check Power And Controls
Verify the thermostat is set to cool and the temperature is below room temp setting. Inspect the breaker panel for a tripped breaker and reset if needed. Ensure the outdoor unit’s disconnect switch is on.
Inspect Air Filters And Vents
Replace or clean the air filter if dirty. Ensure supply and return vents are open and unobstructed. Good airflow is critical for heat transfer and preventing coil freezing.
Examine Outdoor Unit And Coils
Look for debris, leaves, or vegetation blocking the outdoor condenser. Clean the fins gently with a soft brush and hose at low pressure. Avoid bending fins and never spray high-pressure water directly at electrical components.
Call 888-896-7031 for Free Local HVAC Quotes – Compare and Save Today!
Look For Frozen Evaporator Coil Signs
Ice on the indoor coil or refrigerant lines indicates possible low refrigerant or airflow problems. Turn off cooling and run the fan-only mode to thaw the coil before further inspection.
Listen For Unusual Noises
Clicking, humming, or grinding noises may indicate capacitor failure, compressor issues, or fan motor problems. These sound clues help determine whether to call a professional.
Reset The System
After basic checks, reset the thermostat and breakers. Sometimes control boards or safety switches require a power cycle to clear faults. Wait several minutes before restoring power to allow capacitors to discharge.
DIY Fixes Homeowners Can Safely Attempt
Replace Or Clean Filters
Replacing a clogged filter is the simplest fix and often restores airflow and cooling. Recommended replacement frequency is every 1–3 months depending on use and indoor air quality.
Clear Outdoor Unit Obstructions
Remove leaves and debris from around the outdoor unit. Maintain at least 2 feet of clearance to ensure adequate airflow. Straighten bent fins with a fin comb to improve heat exchange.
Check Thermostat Batteries And Settings
Replace thermostat batteries and verify correct wiring and mode. Consider upgrading to a programmable or smart thermostat for better control and diagnostics.
Defrost Frozen Coils
If coils are frozen, turn off the compressor and run the indoor fan or heat to melt ice. After thawing, inspect filters and airflow paths before restarting cooling to prevent re-freezing.
When To Call A Professional Technician
Contact a licensed HVAC technician if the problem involves refrigerant leaks, compressor failure, electrical component replacement, reversing valve issues, or persistent performance problems after basic troubleshooting. Working with refrigerant and high-voltage components requires certification and specialized tools.
What To Expect From A Pro Diagnosis
A technician will perform a complete system evaluation including measuring refrigerant pressures, testing electrical components and capacitors, inspecting the reversing valve and defrost system, and checking airflow and ductwork. They will also test the thermostat and control board for faults.
Estimated Repair Costs And Timeframes
Repair costs vary widely depending on the fault. Minor fixes like filters, cleaning, or capacitors typically cost $100–$400. Refrigerant leak detection and recharge ranges $300–$800 depending on refrigerant type and leak complexity. Compressor replacement can cost $1,200–$4,000 including labor. Repairs generally take 1–4 hours; major component replacements may take longer.
Preventive Maintenance To Avoid Cooling Failures
Regular Inspections And Tune-Ups
Annual professional maintenance in spring helps ensure the Goodman heat pump is ready for cooling season. A tune-up includes cleaning coils, checking refrigerant, testing electrical components, and calibrating controls.
Keep Filters And Coils Clean
Change filters regularly and schedule coil cleanings as needed. Maintaining clean coils improves efficiency and reduces the risk of freezing and compressor failure.
Maintain Proper Thermostat Settings
Use programmable schedules to reduce wear and prevent short cycling. Keep thermostat sensors unobstructed and avoid locating thermostats near heat sources or direct sunlight.
Ensure Proper Ductwork And Insulation
Leaky or poorly insulated ducts reduce system capacity. Sealing and insulating ducts improves cooling distribution and reduces strain on the heat pump.
Troubleshooting Table: Symptoms, Causes, Actions
| Symptom | Possible Causes | Immediate Action |
|---|---|---|
| Outdoor Unit Not Running | Tripped Breaker, Disconnected Power, Faulty Contactor | Check Breaker And Disconnect, Inspect For Visible Damage |
| Air Blowing Warm | Low Refrigerant, Reversing Valve Issue, Compressor Fault | Check Airflow, Call Technician For Refrigerant/Compressor |
| Short Cycles | Thermostat, Low Refrigerant, Compressor Overload | Check Thermostat Settings, Inspect For Ice/Filters |
| Frozen Coil | Low Airflow, Low Refrigerant | Turn Off Compressor, Thaw, Replace Filters, Call Pro |
Goodman Heat Pump Warranties And Parts
Goodman typically offers limited warranties on compressors, parts, and heat exchangers. Warranty terms vary by model and registration status. Homeowners should check the appliance’s serial number and registration for specific coverage and keep service records to support warranty claims.
When Replacement Is The Best Option
Consider replacement when the heat pump is older than 10–15 years, the compressor has failed, or repair costs exceed 50% of replacement cost. New systems offer improved efficiency, quieter operation, and better reliability, often delivering lower operating costs.
Energy Efficiency And Savings Tips
Optimize cooling efficiency by upgrading to a higher SEER-rated heat pump, using a programmable thermostat, sealing ducts, and improving home insulation. Regular maintenance can preserve efficiency and reduce utility bills.
Frequently Asked Questions
Why Does The Heat Pump Run But Not Cool The House?
This often indicates low refrigerant charge, restricted airflow, a malfunctioning reversing valve, or compressor inefficiency. A professional diagnosis can pinpoint the specific cause.
Can A Homeowner Add Refrigerant?
Adding refrigerant requires EPA certification and specialized gauges. It is not recommended as a DIY task because overcharging or misdiagnosing leaks can cause more damage and violate regulations.
How Long Should A Goodman Heat Pump Last?
With proper maintenance, a Goodman heat pump typically lasts 10–15 years. Lifespan depends on usage patterns, maintenance history, and installation quality.
Does Freezing Always Mean Leaks?
Freezing can result from low refrigerant, but it can also be caused by airflow issues like clogged filters or blocked vents. Always address airflow before assuming a refrigerant leak.
Choosing A Qualified HVAC Technician
Select a licensed, insured technician with Goodman experience and positive local reviews. Request an estimate detailing parts, labor, warranties, and refrigerant charges. Verify credentials and ask about diagnostic fees and guarantees on repairs.
Key Takeaways
Goodman heat pump not cooling issues often trace to refrigerant levels, airflow problems, electrical faults, or compressor and reversing valve failures. Homeowners can perform safe checks like inspecting power, filters, and outdoor unit cleanliness, but should call a qualified technician for refrigerant or electrical repairs.
Tips for Getting the Best HVAC Prices
- Prioritize Quality Over Cost
The most critical factor in any HVAC project is the quality of the installation. Don’t compromise on contractor expertise just to save money. - Check for Rebates
Always research current rebates and incentives — they can significantly reduce your overall cost. - Compare Multiple Quotes
Request at least three estimates before making your choice. You can click here to get three free quotes from local professionals. These quotes include available rebates and tax credits and automatically exclude unqualified contractors. - Negotiate Smartly
Once you've chosen a contractor, use the proven strategies from our guide — How Homeowners Can Negotiate with HVAC Dealers — to get the best possible final price.