How to Reset Payne Furnace Code 33

The Payne Furnace Code 33 Reset guide explains what Code 33 means, safe troubleshooting steps, and how to reset the system properly to restore heat. The article focuses on practical, safety-first instructions for homeowners and technicians working with Payne packaged and furnace models. Follow manufacturer guidelines and local codes; if in doubt, contact a licensed HVAC technician.

Item Quick Summary
Code 33 Meaning Ignition lockout due to repeated flame failure or ignition attempts
Common Causes Ignitor failure, dirty burners, gas supply issue, flame sensor fault
Safe Reset Steps Power cycle, check gas, inspect ignitor/flame sensor, reset control per manual
When To Call Pro Persistent lockouts, gas smell, unclear wiring, complex part replacement

What Payne Furnace Code 33 Means

Code 33 on Payne furnaces typically denotes an ignition failure or flame rollout lockout after multiple unsuccessful attempts to light the burners. The control board records repeated ignition attempts that failed to sense a safe, sustained flame, so it locks out the ignition to prevent dangerous conditions.

Why Code 33 Occurs: Common Causes

Understanding common causes helps prioritize troubleshooting. Code 33 often originates from one or more of the following issues.

Ignitor Or Hot Surface Igniter Fault

Cracked, worn, or electrically failed ignitors cannot produce enough heat to ignite the gas. Symptoms include visible breakage, a non-glowing element, or intermittent operation. Hot surface igniters degrade with age and cycling.

Flame Sensor Problems

A dirty or failing flame sensor can’t detect flame even when burners light. This causes the control board to shut the gas valve during trials, producing an ignition lockout after repeated failures.

Gas Supply Or Pressure Issues

Insufficient gas pressure, a closed gas valve, or a blocked gas line prevents adequate fuel from reaching the burners. This is a critical safety area to check if burners do not light or sputter.

Call 888-896-7031 for Free Local HVAC Quotes – Compare and Save Today!

Burner Or Orifice Obstructions

Dirt, rust, or spider webs in burners and orifices reduce flame stability. Poor combustion or delayed ignition may trigger multiple unsuccessful ignition cycles and then code 33.

Draft And Venting Problems

Negative pressure, blocked vents, or closed dampers can cause flame rollout or incomplete combustion, prompting the control to lock out to prevent carbon monoxide risk.

Safety First: Before Any Troubleshooting

Prioritize safety. If a gas odor is present, evacuate immediately and call the gas company or 911. Turn off the gas supply at the appliance only if trained to do so. Always shut off electrical power before inspecting internal components.

Tools And Materials Needed

Gather common HVAC tools before starting: multimeter, insulated screwdrivers, nut drivers, soft brush, fine-grit sandpaper or emery cloth, replacement ignitor or flame sensor (if needed), safety gloves, and a flashlight. A copy of the Payne furnace manual or wiring diagram is helpful.

Step-By-Step Payne Furnace Code 33 Reset Procedure

The following steps guide a safe and methodical reset and troubleshooting process. Each step includes checks to identify root causes before performing a reset.

Step 1: Power Cycle The Furnace

Turn off the furnace power at the thermostat and the service switch or circuit breaker. Wait 60 seconds, then restore power. Power-cycling clears transient faults and may reset the control board from Code 33. If the code returns immediately, proceed to deeper troubleshooting.

Call 888-896-7031 for Free Local HVAC Quotes – Compare and Save Today!

Step 2: Observe The Control Board Lights And Diagnostics

Many Payne control boards use LED pulses to indicate specific fault codes. Record the blink pattern or LCD code. Consult the furnace’s service manual to confirm that the status corresponds to Code 33 or ignition lockout conditions.

Step 3: Check The Gas Supply

Confirm the home’s main gas valve is open and the furnace gas shutoff is in the ON position. If other gas appliances work, the supply is likely OK. If in doubt, or if small pilot flames or weak burners are observed, contact the gas utility or a licensed technician to test pressure.

Step 4: Inspect The Ignitor

Visually inspect the hot surface ignitor for cracks or damage. Use a multimeter to test resistance per the manufacturer’s specification; a failed reading indicates replacement. Replace the ignitor with the exact OEM part and torque mounting screws to avoid stress.

Step 5: Clean Or Replace The Flame Sensor

Remove the flame sensor and gently clean with fine-grit sandpaper or emery cloth until metal is bright. Reinstall and test. If cleaning doesn’t restore reliable flame sensing, replace the sensor. Contaminated sensors are a frequent cause of repeated lockouts.

Step 6: Inspect Burners And Orifices

Remove the burner access panel and visually inspect for dirt, rust, or insect nests. Clean burners with a soft brush and compressed air, and clear orifices if safe to do so. Ensure proper burner alignment and secure mounting.

Step 7: Verify Venting And Combustion Air

Check external vents and flues for obstructions such as bird nests, debris, or snow. Confirm combustion air intake is clear and any induced draft fans operate. Restricted venting can cause flame rollout and ignition problems.

Step 8: Reset The Control Board

After correcting issues, reset the control by cycling power or using the furnace’s reset procedure per the manual. Many Payne units reset after a 3-minute power interruption; others require a specific reset button sequence. Document board LED status to confirm the code no longer appears.

Step 9: Run Several Heat Cycles

Run the furnace through multiple heat calls to ensure reliable ignition and flame sense. Monitor for delayed ignition, abnormal noises, recurrence of Code 33, or unusual smells. Continued intermittent faults indicate deeper problems requiring professional diagnostics.

Troubleshooting Tips And Diagnostic Checks

These checks help isolate intermittent or hard-to-find issues linked to Code 33.

  • Test Ignitor Voltage: Measure voltage to the ignitor during a call for heat to confirm the control board is driving the element.
  • Check Flame Sensor Signal: Use a multimeter or amp clamp (if available) to confirm microamp signal when flame is present.
  • Monitor Gas Valve Operation: Listen for valve clicks and verify line voltage to the valve; a failing valve may open slowly or inconsistently.
  • Scan Error History: Some controls store an error log; review it for patterns that point to intermittent pressure drops or airflow issues.

When To Call A Licensed HVAC Technician

Code 33 resets are safe when caused by a simple dirty sensor or ignitor replacement. However, situations requiring professional service include persistent lockouts, suspected gas leaks, complex control board faults, venting repairs, or inability to isolate the problem. A licensed technician can perform combustion analysis, gas pressure tests, and safe replacements.

Parts Replacement And Costs

Typical replacement parts and estimated cost ranges (parts only) are: ignitor $25–$120, flame sensor $15–$60, gas valve $150–$400, control board $150–$500. Labor varies widely; expect higher costs for complex diagnostics or emergency service calls.

Preventive Maintenance To Avoid Code 33

Regular maintenance reduces the chance of ignition lockouts. Recommended preventive steps include annual professional tune-ups, cleaning burners and sensors, inspecting vents, and testing gas pressure and combustion efficiency. Replace aging ignitors proactively before they fail.

FAQ: Quick Answers About Payne Furnace Code 33 Reset

Can A Homeowner Reset Code 33?

Yes, homeowners can perform basic resets and visual inspections, but should not attempt gas valve, control board, or complex venting repairs unless qualified.

How Many Times Will The Furnace Try To Ignite Before Lockout?

Most controls attempt 2–5 ignition trials before locking out and displaying Code 33. The exact count depends on the control board model.

Is It Safe To Reset Repeatedly?

Occasional resets are acceptable after corrective action, but repeatedly resetting without addressing the root cause can create unsafe conditions. Persistent ignition failures require professional intervention.

Useful Resources And Manufacturer Guidance

Consult the Payne furnace owner’s manual and the technical service bulletin for model-specific diagnostics and LED code definitions. Manufacturer support lines and local authorized dealers provide model-specific parts and documented repair procedures.

Payne/Lennox Support and local HVAC associations offer resources for finding licensed technicians. Always reference the furnace model number and serial when seeking parts or support.

Key Takeaways

Payne Furnace Code 33 indicates ignition lockout caused by repeated flame failures. Safe resolution requires a methodical approach: power cycle, inspect and test ignitor and flame sensor, verify gas supply and venting, clean burners, and reset the control per the manual. Persistent or safety-related issues should be handled by a licensed HVAC professional.

Tips for Getting the Best HVAC Prices

  1. Prioritize Quality Over Cost
    The most critical factor in any HVAC project is the quality of the installation. Don’t compromise on contractor expertise just to save money.
  2. Check for Rebates
    Always research current rebates and incentives — they can significantly reduce your overall cost.
  3. Compare Multiple Quotes
    Request at least three estimates before making your choice. You can click here to get three free quotes from local professionals. These quotes include available rebates and tax credits and automatically exclude unqualified contractors.
  4. Negotiate Smartly
    Once you've chosen a contractor, use the proven strategies from our guide — How Homeowners Can Negotiate with HVAC Dealers — to get the best possible final price.

Leave a Comment