Lennox Furnace Primary and Secondary Limit Switches Open: Causes, Diagnosis, and Fixes

The primary and secondary limit switches on a Lennox furnace protect the system by shutting off heat when temperatures get too high or when airflow is restricted. This article explains what “Limit Switch Open” means, common causes, diagnostic steps, safety considerations, and professional repair guidance to get the furnace back to safe operation.

Symptom Possible Causes Immediate Action
Furnace Shuts Off During Heat Cycle Dirty filters, blocked vents, failed blower, faulty limit switch Turn off furnace, check filters and vents
Limit Switch Tripped (Open) Error Code Overheating, flame rollout, shorted wiring, failed control board Inspect for visible damage, call technician if unsure

What Does “Primary/Secondary Limit Switch Open” Mean

A furnace limit switch is a safety device that monitors the temperature inside the heat exchanger or furnace cabinet. When the control board sees a limit switch show an open state, it interprets that as a tripped or failed condition and will interrupt the heating cycle to prevent overheating or fire risk.

The primary limit switch typically monitors the immediate heat exchanger area or plenum, while the secondary limit switch provides redundancy or monitors another zone to ensure safe operation. If either reads open, the furnace may refuse to run the burners or blower.

Common Causes Of Limit Switch Open Conditions

Several mechanical, electrical, and airflow issues can cause limit switches to open. Identifying the root cause is essential to prevent repeated tripping.

  • Restricted Airflow: Dirty air filters, closed or blocked supply/return registers, or obstructed ductwork raise cabinet temperature.
  • Blower Failure: A malfunctioning blower motor or fan capacitor reduces airflow across the heat exchanger causing overheating.
  • Incorrect Furnace Sizing/Operation: Short-cycling or oversized equipment can produce higher than expected temperatures.
  • Faulty Limit Switch: Age, corrosion, or mechanical failure can make the switch open even when temperatures are normal.
  • Wiring Or Control Board Problems: Loose wires, shorts, or a failing control board can report false open signals.
  • Heat Exchanger Issues: Cracks or internal problems can create unsafe conditions and cause safeties to trip.

Symptoms And Diagnostic Clues

Recognizing the pattern of symptoms helps narrow the cause. Typical indicators include furnace lockouts, error codes on the control board, or unusual overheating smells.

  • Frequent Trips During Heat-Up: Suggests airflow restriction or weak blower performance.
  • One-Time Trip After Service: Could be wiring disturbed or a switch damaged during maintenance.
  • Code On Control Board Or LED Blink Pattern: Lennox furnaces often use blink patterns or fault codes; check the manual for the specific meaning of a primary/secondary limit open indicator.
  • Burner Runs Then Shuts Off: Overheat protection activating mid-cycle is a classic limit trip symptom.

Step-By-Step Diagnostic Checklist

This checklist proceeds from safe, homeowner-friendly checks to tasks that require a trained technician. Always shut power off before inspecting electrical components.

Call 888-896-7031 for Free Local HVAC Quotes – Compare and Save Today!

  1. Confirm The Error: Observe the control board LED or furnace display and verify the exact fault code or message.
  2. Check Air Filter And Registers: Replace dirty filters and ensure all supply and return registers are open and unblocked.
  3. Inspect Blower Operation: With the furnace on and the cabinet open, verify the blower runs when expected and that air volume is normal.
  4. Look For Restricted Vents Or Closed Dampers: Ensure whole-home ventilation isn’t impeded by closed zone dampers or blocked ductwork.
  5. Examine Wiring And Connections: Visually inspect limit switch wiring for loose terminals, frayed wires, or corrosion. Tighten any accessible, safe connections after power is off.
  6. Measure Temperature And Switch Continuity (Technician): Use a multimeter to test switch continuity at ambient and at temperature; measure cabinet and heat exchanger temperatures to gauge overheating.
  7. Check Control Board Inputs: Verify the control board reads the switch states correctly; a faulty board can misinterpret signals.

How To Test A Limit Switch Safely

Testing limit switches involves electrical tools and temperature understanding. If the homeowner is not comfortable or knowledgeable about HVAC electrical work, hire a licensed technician.

  1. Turn Off Power To Furnace: Switch off the furnace at the service switch and breaker.
  2. Locate The Limit Switches: Primary and secondary switches are typically mounted on the furnace plenum or heat exchanger access plate.
  3. Inspect For Visual Damage: Look for melted plastic, corrosion, or charring which indicate overheating or failure.
  4. Use A Multimeter: With the power off, set the multimeter to continuity or ohms. Check the switch terminals; most limits are normally closed at room temperature and will open when tripped.
  5. Simulate Temperature If Required: A technician can carefully warm the switch to confirm it opens at the specified trip temperature. Do not use open flame; use a heat gun or the appropriate lab method.

Repair And Replacement Options

Repair steps vary by cause. Address the underlying reason for the trip before replacing switches to prevent repeat failures.

  • Airflow Fixes: Replace or clean filters, open registers, and remove duct restrictions. Restore normal blower function.
  • Blower Motor Or Capacitor Repair: Replace faulty motors or capacitors to restore airflow. Technicians will also check motor amp draw and bearings.
  • Limit Switch Replacement: If the switch fails continuity testing or shows physical damage, replace with OEM-specified parts rated for the model.
  • Wiring And Control Board Repairs: Tighten loose connections, repair or replace damaged wiring, and replace the control board if it misreads inputs.
  • Heat Exchanger Or Combustion Issues: If overheating results from combustion problems or a cracked heat exchanger, immediate professional evaluation is required due to safety and carbon monoxide risk.

When To Call A Professional

Professional HVAC service is recommended for electrical diagnostics, blower motor replacement, control board issues, suspected heat exchanger damage, or persistent limit switch trips after basic troubleshooting.

  • Electrical Or Gas Work: Require licensed technicians for safe and code-compliant repairs.
  • Heat Exchanger Concerns: Cracked exchangers pose carbon monoxide risks and often necessitate replacement by a qualified technician.
  • Recurring Trips: If limit switches continue to open after airflow fixes and switch replacement, schedule professional diagnostic service.

Preventive Maintenance To Avoid Future Trips

Regular maintenance reduces the chance of limit switch trips and extends furnace lifespan. Establish a maintenance routine that targets common failure points.

  • Replace The Air Filter Every 1–3 Months: Use the correct MERV rating for the home and system.
  • Schedule Annual Professional Tune-Ups: Include burner inspection, heat exchanger check, and blower performance testing.
  • Keep Vents And Returns Clear: Ensure furniture or stored items don’t block airflow.
  • Monitor For Unusual Smells Or Noises: Early signs of blower strain or combustion problems warrant prompt service.

Safety Considerations And Carbon Monoxide Awareness

Limit switches are part of the furnace’s safety chain. Never bypass or tape a tripped limit switch to force the furnace to run. Bypassing safeties can create dangerous overheating or allow combustion byproducts to enter living spaces.

Install and maintain carbon monoxide detectors near sleeping areas and the furnace room. If there is any concern about heat exchanger integrity or combustion safety, evacuate and call a professional immediately.

Call 888-896-7031 for Free Local HVAC Quotes – Compare and Save Today!

Typical Costs And Timeframes For Repair

Costs vary by region and the nature of repair. Homeowners can expect a range based on common fixes.

Repair Type Typical Cost Range Typical Time
Air Filter Replacement/Basic Cleaning $10–$50 15–30 Minutes
Blower Motor Or Capacitor Replacement $250–$800 1–3 Hours
Limit Switch Replacement (Parts + Labor) $100–$300 30–90 Minutes
Control Board Replacement $300–$900 1–3 Hours
Heat Exchanger Replacement/Replacement Unit $1,500–$5,000+ Several Hours To A Day

Model-Specific Considerations For Lennox Furnaces

Lennox models vary in control schemes and diagnostic codes. Consult the furnace’s data plate and manual for accurate error code interpretation.

Lennox high-efficiency furnaces may include multiple safeties and electronic diagnostics. When reading codes, match the LED blink pattern or error display with the manual to confirm whether the board is flagging a primary or secondary limit fault.

Checklist For Technicians And Advanced DIYers

This checklist focuses on thorough diagnosis and preventing recurrence.

  1. Record Error Codes And Operating Conditions Before Powering Down.
  2. Measure Temperature Rise Across The Heat Exchanger Against Manufacturer Specs.
  3. Test Blower Motor Current Draw And Airflow CFM To Confirm Adequate Ventilation.
  4. Inspect Duct System For Excessive Restrictions Or Closed Dampers.
  5. Verify Proper Venting And Combustion Air Supply For Gas Furnaces.
  6. Confirm Limit Switch Trip Temperatures And Replace With OEM Ratings.
  7. Perform A Full Safety Run Including CO Test If Heat Exchanger Suspected Compromised.

Helpful Resources And Next Steps

Owners should consult the Lennox owner’s manual and the unit’s model-specific service documents for diagnostic codes and wiring diagrams. For complex or safety-critical repairs, contact a licensed HVAC contractor or Lennox-certified technician.

Key next steps: check and replace filters, verify blower operation, note error codes, and call a professional if problems persist or if combustion safety is in question.

Frequently Asked Questions

Can A Homeowner Replace A Limit Switch?

Yes, if comfortable with basic electrical safety and the unit is powered off. However, ensure the replacement switch matches OEM specifications and address underlying causes to prevent repeat trips.

Is It Safe To Temporarily Bypass A Limit Switch?

No. Bypassing safety devices is dangerous and illegal in many jurisdictions. It can lead to overheating, fire, or carbon monoxide hazards.

How Quickly Should A Recurring Limit Trip Be Fixed?

Recurring trips should be addressed immediately. They indicate persistent safety or airflow issues that could escalate into equipment damage or safety risks.

Resources And Links

Refer to the Lennox owner’s manual, manufacturer technical bulletins, and local HVAC codes for authoritative guidance. Search for the specific furnace model number to find wiring diagrams and component lists. Licensed HVAC professionals can provide accurate diagnostics and repair estimates.

Tips for Getting the Best HVAC Prices

  1. Prioritize Quality Over Cost
    The most critical factor in any HVAC project is the quality of the installation. Don’t compromise on contractor expertise just to save money.
  2. Check for Rebates
    Always research current rebates and incentives — they can significantly reduce your overall cost.
  3. Compare Multiple Quotes
    Request at least three estimates before making your choice. You can click here to get three free quotes from local professionals. These quotes include available rebates and tax credits and automatically exclude unqualified contractors.
  4. Negotiate Smartly
    Once you've chosen a contractor, use the proven strategies from our guide — How Homeowners Can Negotiate with HVAC Dealers — to get the best possible final price.

Leave a Comment