Atwood RV Furnace Sail Switch: Diagnosis, Replacement, and Troubleshooting

The Atwood RV furnace sail switch is a small but crucial safety component that ensures the furnace blower is operating before the burner ignites. This article explains how the sail switch works, common symptoms of failure, step-by-step diagnostic procedures, replacement guidance, parts compatibility, and preventive maintenance tips for RV owners and technicians.

Symptom Probable Cause Quick Fix
Furnace lights then shuts off Open sail switch or bad contact Inspect switch and wiring; test continuity
Furnace doesn’t light Blower not running or sail switch stuck Check blower motor, clean switch, replace if needed
Intermittent operation Loose connector or weak spring Tighten connectors; replace switch

What Is An Atwood RV Furnace Sail Switch?

The Atwood RV furnace sail switch is a mechanical air-flow sensor installed in the furnace plenum that detects air movement created by the blower fan. When airflow reaches a set threshold, the sail arm moves and closes electrical contacts that allow the ignition sequence to proceed. If the sail switch does not close, the control board or gas valve prevents burner ignition to avoid unsafe conditions.

How The Sail Switch Works

Inside the sail switch, a lightweight vane or “sail” is attached to a pivot arm and spring. The blower’s air pushes the sail, overcoming the spring tension and moving the arm to actuate an internal microswitch. The switch usually operates on 12V DC and interrupts the ignition circuit. Proper operation requires sufficient airflow, a free-moving vane, and clean electrical contacts.

Common Symptoms Of A Failing Sail Switch

Recognizing sail switch issues early helps prevent cold nights and potentially costly repairs. Common signs include the furnace attempting to start but shutting off before ignition, the blower running without the burners lighting, intermittent furnace operation, and visible physical damage to the switch or vane.

Tools And Safety Before Troubleshooting

Safety is essential when diagnosing furnace components. Suggested tools include a multimeter, needle-nose pliers, small screwdrivers, contact cleaner, and a replacement sail switch if necessary. Always disconnect 12V power and propane before working on the furnace to prevent electrical shock and gas hazards.

Step-By-Step Diagnostic Procedure

1. Visual Inspection

Inspect the sail switch, wiring harness, and connectors for corrosion, burned insulation, or loose terminals. Look for a broken or warped sail, accumulated debris, or any signs of water intrusion near the furnace compartment.

Call 888-896-7031 for Free Local HVAC Quotes – Compare and Save Today!

2. Confirm Blower Operation

With power restored and propane off for safety, activate the furnace to the fan-only mode or during the heating cycle prior to ignition. Verify the blower spins at normal speed and that there are no unusual noises indicating motor issues or obstructed airflow.

3. Observe Sail Movement

Open the access panel and watch the sail while the blower runs. The sail should move freely when airflow starts and return to rest when the blower stops. If the sail remains stationary or moves sluggishly, further testing is required.

4. Continuity And Voltage Testing

Using a multimeter, set to DC voltage, confirm 12V is present at the switch when the blower has reached operating speed. Then set the meter to continuity or resistance and check that the switch closes when the sail is actuated. No voltage may indicate wiring or control board issues; no continuity with voltage present indicates a faulty switch.

5. Bypass Test (Temporary)

Only as a brief diagnostic step and with safety precautions, the switch can be temporarily bypassed by connecting the terminals to simulate a closed switch. If the furnace ignites and operates normally during the bypass, the sail switch is the likely cause. Never leave the switch bypassed for regular operation because it defeats a critical safety function.

Common Causes Of Sail Switch Failure

  • Mechanical Obstruction: Debris, dust, or warped vanes that prevent free movement.
  • Corrosion Or Burned Contacts: Oxidation or arcing on internal contacts reduces conductivity.
  • Weak Spring Or Broken Pivot: Age or fatigue can prevent the sail from actuating at the design airflow.
  • Wiring Problems: Loose connectors, chafed wires, or poor grounds will interfere with operation.
  • Inadequate Airflow: Restricted vents, clogged filters, or a failing blower motor reduce airflow below the switch threshold.

Replacement: Choosing The Correct Atwood Sail Switch

When replacement is necessary, sourcing the correct part is key. Atwood (now Suburban/Atwood lineage) uses specific sail switch models per furnace line. Match the OEM part number printed on the old switch or consult the furnace manual. Generic replacements are available but confirm the mounting style, voltage rating, and sail dimensions.

Common Part Considerations

  • Voltage Rating: Most RV furnace sail switches use 12V DC; verify before installation.
  • Mounting Orientation: Some switches are designed for vertical or horizontal mounting; install in the original position for accurate airflow sensing.
  • Sail Size And Shape: The vane surface area determines actuation sensitivity; use a compatible size to preserve factory thresholds.
  • Connector Type: Pre-crimped spade terminals or pigtail leads should match the furnace harness for secure connections.

How To Replace An Atwood RV Furnace Sail Switch

  1. Disconnect the 12V battery and turn off propane to the RV.
  2. Remove the furnace access panel to expose the switch and harness.
  3. Document or photograph wiring and mounting orientation before removal.
  4. Disconnect electrical connectors and remove any mounting screws or clips holding the switch.
  5. Install the new switch in the same orientation, secure mounting hardware, and reconnect wires using proper terminals.
  6. Restore power and run the furnace through a cycle to verify proper operation and sail movement.

During installation, ensure connectors are tight and protected from moisture. If the replacement switch includes adhesive or foam seals, align them to prevent air bypass that could cause false readings.

Call 888-896-7031 for Free Local HVAC Quotes – Compare and Save Today!

Testing After Replacement

After installing the new sail switch, run several heating cycles and observe for stable operation. Measure 12V at the switch during blower operation and confirm continuity when the sail is actuated. Monitor for any intermittent behavior, unusual blower noise, or temperature cycling that could indicate related problems.

Related Components To Inspect

When addressing sail switch issues, inspect related components that often cause similar symptoms: blower motor and capacitor, furnace limit switch, control module, gas valve and regulator, venting and flue pipe, and thermostat wiring. Addressing only the sail switch may not resolve the underlying cause if airflow remains restricted or the blower is failing.

Preventive Maintenance To Extend Sail Switch Life

  • Keep furnace intake and exhaust vents clear of debris, leaves, or snow buildup.
  • Clean the furnace compartment periodically to remove dust and grit that can foul the sail mechanism.
  • Inspect wiring and harnesses during annual RV service for tight connections and corrosion.
  • Operate the furnace fan mode briefly during off-season storage to prevent stiffening of mechanical parts.
  • Replace foam seals and gaskets that prevent air leaks around the switch housing.

Troubleshooting Tips And Quick Fixes

If the sail switch repeatedly fails soon after replacement, consider these possibilities: incorrect switch part or orientation, excessive vibration causing mechanical wear, persistent moisture ingress, or undersized sail causing premature opening. Swapping with a verified OEM part, applying dielectric grease to connections, and improving drainage or sealing around the furnace will often resolve repeat failures.

When To Call A Technician

Professional service is recommended if the issue involves propane leaks, complex control board faults, or if the blower motor requires replacement. A qualified RV technician can perform combustion testing, verify gas valve operation, and ensure compliance with safety standards. For owners uncomfortable with electrical diagnostics, professional assistance avoids accidental damage or safety risks.

Parts And Resources For American RV Owners

Replacement Atwood sail switches and compatible aftermarket parts are available from major RV parts suppliers, online marketplaces, and authorized dealers. When purchasing, use the furnace model number and existing part number to ensure compatibility. Manufacturer documentation, RV forums, and service manuals are useful resources for wiring diagrams and installation guidance.

Key Takeaways And Best Practices

The sail switch is a small safety device with outsized importance. Regular inspection, proper replacement with compatible parts, and ensuring adequate airflow are the most effective strategies to maintain reliable furnace operation. Documenting observations, testing methodically, and addressing root causes rather than symptoms will reduce repeat failures and keep the RV warm and safe.

For urgent or complex issues, prioritize safety by turning off propane and 12V power and consulting a qualified RV technician. Proper diagnosis and timely replacement of a faulty Atwood RV furnace sail switch restore reliable heating and protect occupants from unsafe combustion conditions.

Tips for Getting the Best HVAC Prices

  1. Prioritize Quality Over Cost
    The most critical factor in any HVAC project is the quality of the installation. Don’t compromise on contractor expertise just to save money.
  2. Check for Rebates
    Always research current rebates and incentives — they can significantly reduce your overall cost.
  3. Compare Multiple Quotes
    Request at least three estimates before making your choice. You can click here to get three free quotes from local professionals. These quotes include available rebates and tax credits and automatically exclude unqualified contractors.
  4. Negotiate Smartly
    Once you've chosen a contractor, use the proven strategies from our guide — How Homeowners Can Negotiate with HVAC Dealers — to get the best possible final price.
Action Estimated Time Difficulty
Visual Inspection And Sail Movement Check 10–20 Minutes Easy
Multimeter Testing And Bypass Diagnostic 15–30 Minutes Moderate
Complete Sail Switch Replacement 30–60 Minutes Moderate