Proper ventilation is critical in paint booths to control fumes, prevent ignition, and maintain air quality. This guide compares five explosion-proof axial fans suitable for paint booths, garages, and industrial ventilation. The summary table below highlights each model’s core specs to help you compare at a glance.
| Product | Brand | Power / Voltage | Airflow / Noise |
|---|---|---|---|
| GMSLuu 16″ Axial Fan | GMSLuu | 370W / 110V | 2675–5400 m³/h |
| MuChaIOAK Explosion-Proof Fan | MuChaIOAK | 370W / 110V | 2880 m³/h / 62 dB |
| NTNOEA 16″ Axial Fan | NTNOEA | 370W / 110V | 2675–5400 m³/h / 71 dB |
| NeNchengLi 16″ Portable Fan | NeNchengLi | 370W / 110V | 2880 m³/h / 62 dB |
| TFCFL 10″ Axial Fan | TFCFL | All Copper Motor | Low noise, large air volume |
Content Navigation
GMSLuu 16″ Axial Fan Cylinder Pipe

The GMSLuu 16″ axial fan is built for high-volume exhaust in commercial and industrial spaces. Its carbon steel shell and stainless steel fan blades offer corrosion and heat resistance suited to paint booth environments. The motor is a pure copper 370W unit with medium-speed bearings delivering a wide airflow range (2675–5400 m³/h) and notable air pressure (98–150 Pa).
Design features emphasize durability and continuous operation. The fan’s four large-angle blades and 1420 rpm speed increase suction capacity for rapid fume removal. The product targets applications in factories, workshops, and ventilation ducts, where stable performance and electricity savings from copper windings are prioritized.
MuChaIOAK Explosion-Proof Axial Fan

MuChaIOAK’s model is explicitly labeled as explosion-proof with an ExdⅡBT4Gb marking and cast iron motor housing for enhanced corrosion resistance. Rated at 370W, 110V, it lists an impeller diameter of 400 mm and spindle speed of 1450 rpm. Published airflow is approximately 2880 m³/h, and noise is specified at 62 dB.
Call 888-896-7031 for Free Local HVAC Quotes – Compare and Save Today!
Key characteristics include a sealed motor, cast iron enclosure for mechanical robustness, and clear safety labeling. The low noise specification and sealed silent ball bearings are relevant where operator comfort and quiet operation are considerations alongside hazardous-environment compliance.
NTNOEA 16″ Axial Explosion-Proof Fan

The NTNOEA unit shares many construction features with other 16″ axial models: carbon steel housing, stainless steel blades, and a pure copper 370W motor. The spec sheet indicates high suction capability with a reported airflow range of 2675–5400 m³/h and 1420 rpm speed. This fan is promoted for multifunctional uses including ventilation, dehumidification, and dust removal.
Installation flexibility is noted: wall or duct mounting is possible to match different paint booth layouts. The product emphasizes durability and continuous ventilation performance in industrial settings where large-volume air exchange is needed to manage combustible vapor concentrations.
NeNchengLi 16″ Portable Explosion-Proof Fan

NeNchengLi’s portable 16″ fan is rated 370W, 110V with a 400 mm impeller and 1450 rpm spindle speed. It carries the ExdⅡBT4Gb explosion-proof mark and protective meshes on both ends to prevent debris ingress. The manufacturer lists airflow at about 2880 m³/h and noise at 62 dB.
Call 888-896-7031 for Free Local HVAC Quotes – Compare and Save Today!
The combination of protective meshes, cast aluminum blades, and a wide-angle outlet supports faster air circulation and safeguards blade integrity. Portability and safety labeling make this model useful for temporary setups, mobile booths, and workshops where protective measures against sparks and debris are necessary.
TFCFL 10″ Axial Explosion-Proof Fan

TFCFL’s 10″ axial fan is a smaller-diameter option emphasizing all-copper motor construction and stainless steel blade design. It features a mesh protective net and explosion-proof labeling for hazardous environments. The product highlights smooth operation, large air volume relative to size, and low noise.
As a compact alternative, this model suits smaller booths, targeted spot ventilation, or duct-fed configurations where a full 16″ unit is unnecessary. The focus on sealing and copper windings supports continuous operation with improved energy efficiency.
Buying Guide: Choosing Explosion-Proof Ventilation For Paint Booths
Selecting ventilation for a paint booth balances safety, airflow, durability, and installation constraints. Below are key considerations to compare models objectively and match a fan to your facility’s needs.
Explosion-Proof Certification And Markings
- Verify Certification: Look for explicit explosion-proof markings such as ExdⅡB T4 or ExdⅡBT4Gb. These indicate the unit’s suitability for flammable vapor atmospheres and temperature class limits.
- Enclosure Material: Cast iron or steel housings with clear labeling improve mechanical protection and corrosion resistance in industrial paint environments.
Airflow Capacity And Pressure
- Airflow (m³/h or CFM): Determine booth volume and required air exchanges per hour. Larger booths need higher m³/h ratings; compact booths may suffice with smaller units.
- Static Pressure: Higher pressure ratings (Pa) help overcome duct resistance, filters, or long duct runs to ensure required flow at the booth face.
Motor Type And Efficiency
- Copper Windings: Pure copper motors typically offer better conductivity, lower running temperatures, and longer life.
- Rated Power Vs. Real Performance: Compare published power (W) to airflow and RPM. Two motors with equal wattage can perform differently based on blade design and bearings.
Noise, Bearings, And Duty Cycle
- Noise Level: dB ratings (when provided) help anticipate operator comfort. Lower dB values are beneficial in occupied spaces.
- Bearings And Sealing: Sealed ball bearings and robust seals extend motor life and reduce maintenance, important for continuous-duty fans.
Blade Design And Materials
- Blade Material: Stainless steel or cast aluminum blades resist corrosion from solvents and humidity common in paint booths.
- Blade Angle And Count: Larger angle blades with efficient geometry increase airflow for given motor power. Four-blade or three-blade designs offer different tradeoffs in pressure vs. volume.
Mounting, Duct Compatibility, And Portability
- Mounting Options: Wall, duct, or portable units serve different use cases. Verify flange dimensions and mounting holes for duct integration.
- Portable Vs. Fixed: Portable fans aid temporary setups and maintenance access; fixed duct fans often provide better sealed exhaust and lower leakage.
Protective Features And Safety
- Protective Meshes And Guards: Prevent foreign debris from contacting blades and creating sparks or mechanical failure.
- Labeling And Instructions: Clear explosion-proof labels, wiring instructions, and safety precautions are essential for compliant installation and inspection.
Maintenance, Serviceability, And Parts
- Spare Parts And Motor Access: Choose designs that allow bearing replacement and motor servicing without full replacement.
- Cleaning And Filter Access: Easy access for cleaning blades and intake areas reduces downtime and retains performance.
Comparison Perspectives
- Performance-Focused: For maximum airflow and pressure, select 16″ units with higher published m³/h and Pa ratings.
- Safety-Focused: Prioritize explicit Ex markings, cast housings, protective meshes, and sealed bearings.
- Space-Focused: For constrained booths, compact 10″ or portable 16″ models may offer better fit without oversized capacity.
- Noise/Comfort-Focused: Use models specifying dB ratings and sealed silent bearings where the booth is near occupied workspaces.
When installing, engage a qualified electrician for explosion-hazard wiring, confirm compatibility with local codes, and size ventilation to booth volume and regulatory air exchange requirements. Proper selection and installation of an explosion-proof axial fan are central to controlling paint booth hazards and maintaining a compliant workspace.
Tips for Getting the Best HVAC Prices
- Prioritize Quality Over Cost
The most critical factor in any HVAC project is the quality of the installation. Don’t compromise on contractor expertise just to save money. - Check for Rebates
Always research current rebates and incentives — they can significantly reduce your overall cost. - Compare Multiple Quotes
Request at least three estimates before making your choice. You can click here to get three free quotes from local professionals. These quotes include available rebates and tax credits and automatically exclude unqualified contractors. - Negotiate Smartly
Once you've chosen a contractor, use the proven strategies from our guide — How Homeowners Can Negotiate with HVAC Dealers — to get the best possible final price.