The Goodman furnace EE5 code signals a control-board communication or sensor fault that can interrupt heating and require targeted troubleshooting. This article explains what the EE5 code on Goodman furnace indicates, common causes, step-by-step diagnostics, safety precautions, practical fixes, preventive maintenance, and guidance on when to call a professional. The goal is to help homeowners and technicians efficiently identify and resolve EE5 issues while maintaining system safety.
| Item | Summary |
|---|---|
| Code | EE5 — Control board / communication/sensor error |
| Common Causes | Faulty flame sensor, open/shorted wiring, defective control board, limit/temperature sensor fault |
| Symptoms | Furnace lockout, flashing LED error, failure to ignite or intermittent operation |
| Initial Steps | Record flashes, reset power, inspect error history, check wiring and sensors |
Content Navigation
- What The EE5 Code Means
- How Goodman Displays Error Codes
- Common Causes Of EE5 On Goodman Furnaces
- Safety First: Before Troubleshooting
- Tools And Materials Needed
- Step-By-Step Troubleshooting Guide
- When To Replace Parts
- Temporary Workarounds And What They Mean
- Manufacturer Resources And Manuals
- Costs And Time Estimates
- When To Call A Professional
- Preventive Maintenance To Avoid EE5
- Warranty And Safety Considerations
- FAQ About EE5 Code On Goodman Furnace
- Useful Diagnostic Checklist
- Final Practical Tips
What The EE5 Code Means
The EE5 code on a Goodman furnace generally indicates a communication or sensor error reported by the furnace control board. Depending on the model, EE5 may be logged as an electronic error involving the flame sensing circuit, limit/temperature inputs, or inter-board communication. The control board detects a condition outside expected parameters and prevents normal operation to avoid unsafe conditions.
How Goodman Displays Error Codes
Goodman furnaces use an LED on the control board to flash fault codes. Each code is communicated as a series of long and short flashes or numeric pairs. A service manual for the specific model provides the exact flash pattern and associated diagnostics. Always record the LED flash sequence and refer to the model-specific manual to interpret EE5 accurately.
Common Causes Of EE5 On Goodman Furnaces
- Faulty Flame Sensor: A contaminated or failing flame sensor may not detect flame reliably, leading to an EE5 if the board interprets the signal as abnormal.
- Open Or Shorted Wiring: Damaged wiring or loose connectors between sensors and the control board can produce communication errors.
- Defective Control Board: Internal board faults, corroded connections, or failed components on the board can generate false sensor or communication errors.
- Limit Or Temperature Sensor Problems: High-limit switches, rollout switches, or NTC temperature sensors that are open, shorted, or out of range may trigger EE5.
- External Electrical Issues: Inconsistent power supply, voltage spikes, or poor grounding can disrupt control-board readings and log EE5.
Safety First: Before Troubleshooting
Always prioritize safety. Turn off power to the furnace at the breaker before inspecting wiring, sensors, or the control board. Use a multimeter rated for household circuits and wear appropriate protective equipment. If the homeowner is not comfortable performing electrical diagnostics, contact a licensed HVAC technician.
Tools And Materials Needed
- Multimeter with continuity, resistance, and voltage measurement
- Screwdrivers and nut drivers for access panel removal
- Small brush or emery cloth for cleaning the flame sensor
- Manufacturer’s service manual or access to wiring diagrams
- Replacement sensors or control board (if required)
Step-By-Step Troubleshooting Guide
1. Record The Error Pattern
Restore power briefly to note the LED flash pattern if it cleared after a reset. Write down the sequence and consult the model-specific service manual to confirm the EE5 description and recommended diagnostics.
2. Check Power And Reset
Verify the furnace has proper 120V power and the gas supply is on. Reset the furnace by switching off the breaker for 60 seconds and then restoring power. If the EE5 returns immediately, proceed to targeted diagnostics.
Call 888-896-7031 for Free Local HVAC Quotes – Compare and Save Today!
3. Inspect Visual Wiring And Connections
Open the access panel and visually inspect connectors to the control board, flame sensor, limit switches, and temperature sensors. Look for loose pins, burnt insulation, corrosion, or rodent damage. Tighten or reseat connectors where appropriate.
4. Test Flame Sensor
With power off, remove the flame sensor and inspect for carbon buildup. Clean gently with fine emery cloth. Reinstall and test operation. If cleaning does not restore operation, measure resistance if specified or replace the sensor. A failing sensor may trigger EE5-like errors when the board receives erratic signals.
5. Check Limit And Rollout Switches
Use a multimeter to test continuity across the high-limit and rollout switches. With the furnace cold and power off, each switch should show continuity if closed. An open switch indicates an overheat or failed component that can cause protective error codes.
6. Verify Sensor Wiring Integrity
Measure continuity and resistance of wires from sensors to the control board. Compare readings to manufacturer specifications. Intermittent open circuits or shorts will create communication errors. Repair or replace damaged wiring or harnesses.
7. Inspect Control Board For Damage
Look for burn marks, swollen capacitors, or loose micro-connectors on the control board. If the board shows physical damage, replacement is often required. Document any fault history because intermittent board issues may need a professional evaluation.
8. Monitor System Operation With Multimeter
With the system energized, measure expected voltages at sensor inputs and evaluate whether the control board receives valid signals. Fluctuating or out-of-range voltages support a sensor or wiring fault diagnosis versus a simple reset fix.
Call 888-896-7031 for Free Local HVAC Quotes – Compare and Save Today!
When To Replace Parts
Replace the flame sensor if cleaning and testing fail to produce reliable flame detection. Replace wiring harnesses that show damaged insulation or intermittent continuity. Replace the control board when diagnostics point to internal failures, recurring false faults appear after sensor and wiring checks, or when the board displays multiple unrelated errors.
Temporary Workarounds And What They Mean
Resetting the furnace can clear an EE5 temporarily, but repeated resets indicate an unresolved underlying fault. Temporary workarounds such as bypassing a limit switch are unsafe and not recommended. Address root causes rather than relying on resets to avoid dangerous conditions and preserve warranty coverage.
Manufacturer Resources And Manuals
Goodman provides model-specific service manuals and wiring diagrams which are essential for accurate EE5 diagnosis. The exact EE5 definition and LED flash patterns vary by control-board family, so reference the manual for the furnace model before replacing major components.
Costs And Time Estimates
Costs vary: a replacement flame sensor typically runs $15–$60, a wiring harness $30–$150, and a control board $200–$600 parts only. Labor for a professional HVAC technician ranges from one to three hours depending on diagnosis complexity. Expect higher costs if multiple components require replacement or if board reprogramming is necessary.
When To Call A Professional
- Persistent EE5 after basic checks and sensor cleaning
- Visible control-board damage or burnt components
- Complex wiring faults or intermittent errors that require advanced testing
- Homeowner uncertainty around electrical testing or gas system components
Calling a licensed technician ensures safety, precise diagnosis, and correct replacement parts with factory-compatible programming and testing.
Preventive Maintenance To Avoid EE5
- Annual professional tune-ups including sensor inspection and control-board diagnostics
- Keep the furnace area clean and free from dust and debris
- Change air filters regularly to prevent overheating and limit trips
- Inspect wiring and connectors for rodent or mechanical damage periodically
- Address intermittent performance issues promptly to avoid escalation
Warranty And Safety Considerations
Before attempting board replacements or internal repairs, check the furnace warranty terms. Unauthorized modifications or non-certified parts can void warranties. For safety, never bypass safety switches or disconnect essential sensors to force operation.
FAQ About EE5 Code On Goodman Furnace
What Does EE5 Typically Point To?
EE5 commonly points to control-board-detected sensor or communication anomalies, frequently involving the flame sensing circuit, limit switches, or inter-board connections.
Can A Dirty Flame Sensor Cause EE5?
Yes. A contaminated flame sensor can produce intermittent or no flame detection signals, which the control board may interpret as an EE5 error.
Is It Safe To Reset The Furnace Repeatedly?
Occasional resets during troubleshooting are acceptable, but repeated resets mask unresolved faults. Persistent errors should be evaluated by a professional to maintain safety and reliability.
How Long Will Fixing EE5 Take?
Simple fixes like cleaning a flame sensor can take 15–30 minutes. Complex diagnostics involving wiring or control-board replacement may take one to several hours.
Useful Diagnostic Checklist
- Record the LED error flash pattern and consult the model manual
- Power-cycle the furnace and note whether the code reappears
- Inspect wiring harnesses and connectors for damage
- Clean and test the flame sensor
- Test limit switches and temperature sensors for continuity
- Measure voltages at sensor inputs with the system powered
- Inspect the control board for physical damage and replace if necessary
Final Practical Tips
Document the problem, repairs performed, and any parts replaced for future reference. Keep the model and serial number handy when ordering parts or scheduling service. When in doubt, prioritize safety and consult a licensed HVAC technician to ensure correct diagnosis and repair.
If the EE5 code continues after following the steps above, contacting a certified Goodman technician or the manufacturer’s support line provides model-specific troubleshooting and parts guidance.
Tips for Getting the Best HVAC Prices
- Prioritize Quality Over Cost
The most critical factor in any HVAC project is the quality of the installation. Don’t compromise on contractor expertise just to save money. - Check for Rebates
Always research current rebates and incentives — they can significantly reduce your overall cost. - Compare Multiple Quotes
Request at least three estimates before making your choice. You can click here to get three free quotes from local professionals. These quotes include available rebates and tax credits and automatically exclude unqualified contractors. - Negotiate Smartly
Once you've chosen a contractor, use the proven strategies from our guide — How Homeowners Can Negotiate with HVAC Dealers — to get the best possible final price.